Cookies help us to provide our services in high quality. By using our services, you agree that we use cookies. For more information see our Privacy Policy.

Magnetic, compact, reliable

 
Built with Neodymium magnets and thus compatible with a wide range of metallic materials without the need for electricity. Load capacities from 150 kg / 350 lbs to 2,000 kg / 4,400 lbs. Simple and quick to mount to the lifting equipment thanks to permanently mounted master links. Suitable for flat and round material and as well for temperature ranges from -10 °C to +80 °C at 80 % maximum humidity. Maximum temperature of the load to be lifted: 60 °C.
 
Surface: orange, anodized and electro galvanized.
Master links: orange, powder-coated.
 
Manufactured according to EN 12100 T1 and T2, EN 13155, ASME B30.20 and Machinery Directive 2006/42/EC.








Type A B C D E Master link Weight
[mm / in] [mm / in] [mm / in] [mm / in] mm / in kg/lbs
PMA 150 85.00 / 3.35 110.00 / 4.33 155.00 / 6.10 85.00 / 3.35(1) 190.00 / 7.48 AW 13: 13x110x60 7.00 / 15.43
PMA 300 85.00 / 3.35 110.00 / 4.33 195.00 / 7.68 85.00 / 3.35 190.00 / 7.48 AW 13: 13x110x60 9.00 / 19.84
PMA 500 110.00 / 4.33 130.00 / 5.12 260.00 / 10.23 105.00 / 4.13 250.00 / 9.48 AW 13: 13x110x60 17.00 / 37.50
PMA 1000 130.00 / 5.12 175.00 / 6.89 320.00 / 12.60 135.00 / 5.31 275.00 / 10.87 AW 13: 13x110x60 40.00 / 88.20
PMA 2000 205.00 / 8.07 230.00 / 9.05 450.00 / 17.72 180.00 / 7.09 510.00 / 20.08 AW 22: 23x160x90 112.00 / 246.90
Flat surface Round surface
Type WLL Min. material Max. length L WLL Max. material
[kg / lbs] thickness [mm / in] [mm / in] [kg / lbs] diameter [mm / in]
PMA 150 150 / 330 20.00 / 0.79 2.000 / 78.74 75 / 150 150.00 / 5.91
PMA 300 300 / 700 20.00 / 0.79 2.500 / 98.43 150 / 350 150.00 / 5.91
PMA 500 500 / 1.100 25.00 / 0.98 3.000 / 118.11 250 / 550 250.00 / 9.84
PMA 1000 1.000 / 2.200 35.00 / 1.38 3.500 / 137.80 500 / 1.100 300.00 / 11.81
PMA 2000 2.000 / 4.400 45.00 / 1.77 3.500 / 137.80 1.000 / 2.200 500.00 / 19.69
Restrictions of use
Temperature range From -10° C to +80° C and max. humidity of 80 % Less than -10° C and more than +80° C
Load factor 1 Not permitted
Shock loading Not permitted
Steel type Mild steel Alloy steel C40 steel Cast iron
Load factor 1 0.8 0.7 0.45